Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.425
Filtrar
1.
J Hazard Mater ; 470: 134219, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38615647

RESUMO

Disposable surgical masks undeniably provide important personal protection in daily life, but the potential health risks by the release of microplastic fibres from masks should command greater attention. In this study, we conducted a microplastic fibre release simulation experiment by carrying masks in a pocket and reusing them, to reveal the number and morphological changes of microfibres released. Fourier transform infrared spectrometry, scanning electron microscopy, and optical microscopy were employed to analyse the physical and chemical characteristics of the mask fibres. The results indicated that the reuse of disposable masks led to a significant release of microplastic fibres, potentially leading to their migration into the respiratory system. Furthermore, the release of microplastic fibres increased with prolonged external friction, particularly when masks were stored in pockets. The large-scale release of microplastic fibres due to mask reuse raises concerns about potential health risks to the human respiratory system. The reuse of disposable masks should be also strictly avoided in daily life in the future. Furthermore, the current study also established a robust foundation for future research endeavours on health risks associated with microplastic fibres entering the respiratory system through improper mask usage.


Assuntos
Máscaras , Microplásticos , Humanos , Microplásticos/análise , Microplásticos/toxicidade , Equipamentos Descartáveis , Reutilização de Equipamento , Espectroscopia de Infravermelho com Transformada de Fourier
3.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 111-113, 2024 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-38384229

RESUMO

Objective: To explore the effect of routine reusable pipeline and disposable pipeline on ventilator quality control results. Methods: 17 ventilators were randomly selected to conduct quality control using routine reusable pipeline and disposable pipeline respectively. Quality control data were recorded and then paired t-test method was used to analyze whether the difference between the two pipelines was significant or not. Results: There were no significant differences in respiratory rate, tidal volume and end airway pressure between the two types of pipes ( P>0.05). The airway peak pressure of routine reusable pipeline was significantly higher than disposable pipeline ( P<0.05), but the difference was very small, only about 0.2 mbar which would not affect the conclusion of quality control. Conclusion: Quality control of ventilator is not affected by routine reusable pipeline and disposable pipeline, which can be replaced by each other.


Assuntos
Equipamentos Descartáveis , Ventiladores Mecânicos , Volume de Ventilação Pulmonar
6.
8.
Ann R Coll Surg Engl ; 106(2): 167-172, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37051744

RESUMO

INTRODUCTION: After excluding anaesthetic gases, around one-third of carbon emissions from surgical procedures are from consumables. This sustainable quality improvement project revised the laparoscopic appendicectomy surgical set at a large teaching hospital, with the aim of reducing unnecessary usage of disposable laparoscopic ports and surgical instruments. METHODS: A prospective audit of 25 consecutive laparoscopic appendicectomies (5% of annual appendicectomies performed at the Trust) was conducted to assess use of disposable instruments. The financial and environmental costs of the five most commonly used disposable instruments were calculated and annual cost of current practice determined. A revised surgical set was created to include additional reusable instruments and new reusable ports. A reaudit of disposable surgical instrument usage was conducted and the financial and environmental impact of the new set compared with the results from the initial audit. RESULTS: A total of 109 disposable instruments were opened in 25 appendicectomies, costing an estimated £49,656 and 692kg CO2 equivalent (CO2e) annually. Following rollout of the revised appendicectomy set, there was a significant reduction in disposable instrument usage (median four versus one instruments per case, p<0.00001). The revised set is predicted to reduce annual disposable instrument usage from 2,180 to 705 instruments (68% reduction), saving £219,452 and 3.02 tonnes CO2e over the estimated seven-year lifecycle of the reusable instruments. CONCLUSIONS: Updating a laparoscopic appendicectomy set to include additional/new reusable instruments can lead to a marked reduction in disposable surgical instrument usage. This results in significant projected financial and CO2e savings.


Assuntos
Equipamentos Descartáveis , Laparoscopia , Humanos , Reutilização de Equipamento , Instrumentos Cirúrgicos , Apendicectomia/métodos
9.
J Endourol ; 38(1): 68-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37885229

RESUMO

Introduction: Single-use medical devices (SUDs) are labeled for single use only, but rising health care costs along with the absence of visible deterioration in the quality of SUDs after one use have led to their reprocessing and reuse. In the past, SUDs mainly consisted of equipment such as guidewires and catheters. However, SUDs have now expanded to flexible endoscopes and energy devices that are much more expensive. Reuse of such devices raises concerns of infection transmission, safety, and lack of effectiveness. We reviewed the disinfection process, cost benefits, potential harms, and legal status of the reuse of SUDs in endourology. Materials and Methods: PUBMED, Embase, and the Cochrane Library databases were searched for articles published between 1970 and March 2023 that reported the reuse of SUDs using the search terms "reuse"; "single-use device"; "disposable medical devices"; "reprocessing of single-use device"; "endourology"; and keywords related to cost, safety, sterilization, and legal status. Online resources were found using Google search engines. Articles on cost savings, device malfunction, disinfection, or legal status in different countries were reviewed. Results and Conclusions: Reusing SUDs has financial, environmental, and practical advantages. The potential savings on medical expenses is the most compelling argument for reprocessing disposable devices. Reusing medical equipment also contributes to the reduction of toxic biodegradable waste. However, there is a scarcity of data on the safety and efficacy of reused SUDs. For patient safety and to avoid complications, the practice must be regulated with established reprocessing standards.


Assuntos
Equipamentos Descartáveis , Esterilização , Humanos , Custos de Cuidados de Saúde , Análise Custo-Benefício , Reutilização de Equipamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-38083580

RESUMO

This paper aims to question the sustainability of biomedical engineering practices. The strong sustainability framework is applied to the evaluation and development of medical technologies through the definition of clinical sustainability. A roadmap for developing and evaluating medical technologies in this respect is derived from this framework, as a first step toward a multidisciplinary evaluation tool. On this basis, the current trend towards disposable endoscopes is analyzed and discussed. This highlights the subtle balance between economic, clinical, social, and environmental factors, the lack of evidence at these multiple levels, and the need for multidisciplinarity. This paper concludes with the need to assess all aspects of sustainability and identify and quantify the trade-offs, instead of focusing on one or two key indicators, to have more relevant information in order to make better and more effective decisions. Towards sustainable healthcare, we outline two paths of action: (1) providing evidence that is lacking on the environmental impact of existing or currently developed medical technologies and (2) clarifying the premises and visions underlying our practices.Clinical Relevance- This work provides insights regarding the strong sustainability of medical technologies. This clinical framework may help clinicians and developers in decision-making to reduce indirect negative ecological, social, and health impacts.


Assuntos
Equipamentos Descartáveis , Endoscópios , Desenvolvimento Sustentável
12.
Urol J ; 20(6): 424-428, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-37990798

RESUMO

PURPOSE: To evaluate the efficacy of frenulum protection technique of the disposable circumcision suture device (DCSD) in adult males. MATERIALS AND METHODS: Atotal of 53 adult males were diagnosed with redundant prepuce and underwent circumcision with DCSD using frenulum protection technique. The main preoperative and postoperative measure of the length of penile frenulum was evaluated. Other data such as edema rate, intraoperative blood loss, operation time, postoperative pain, staple falling off time, incision infection rate, and evaluation of satisfaction rate with penis appearance were documented in the study. RESULTS: There was no significant difference in preoperative and postoperative frenulum length for each patient. The mean length of the penile frenulum before and after surgery was 2.25 ± 0.36 cm and 2.23 ± 0.39 cm, respectively (p = .31). The rate of frenulum length preservation was 100%. All the patients had no excessive resection of the frenulum and no serious complication happened after surgery. The satisfaction rate of postoperative penis appearance from patients' evaluation was 98.1% (52/53). CONCLUSION: The frenulum protection technique was simple and operable, which could help the operator to accurately identify the most distal position of the frenulum and retain a sufficient length of frenulum during DCSD circumcision.


Assuntos
Circuncisão Masculina , Masculino , Adulto , Humanos , Circuncisão Masculina/métodos , Equipamentos Descartáveis , Pênis/cirurgia , Prepúcio do Pênis , Suturas
14.
Am J Infect Control ; 51(12): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37690482

RESUMO

BACKGROUND: Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance. METHODS: Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels. RESULTS: Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas. CONCLUSIONS: The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.


Assuntos
Isolamento de Pacientes , Roupa de Proteção , Humanos , Equipamento de Proteção Individual , Equipamentos Descartáveis
15.
Eye Contact Lens ; 49(11): 475-482, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707468

RESUMO

OBJECTIVES: To investigate the performance of a novel flat pack toric daily disposable contact lens compared with traditionally packaged toric lenses in a randomized, crossover study. Environmental attitudes to contact lens wear were also explored. METHODS: Habitual contact lens wearers were recruited to wear a hioxifilcon A (Miru 1 day Flat Pack Toric, Menicon, Nagoya, Japan) test lens and a control lens: either nelfilcon A (Dailies AquaComfort Plus, Alcon, Geneva, Switzerland) or etafilcon A (1-Day Acuvue Moist, Johnson & Johnson, New Brunswick, NJ). Objective lens performance was assessed at fitting, and participants wore lenses in a randomized order for three consecutive days. Subjective measures of lens performance (comfort, vision, and handling) were then assessed by a questionnaire, with further questions on overall lens preference and environmental perceptions. RESULTS: Objective measures of lens fit were similar for the test and control lenses, except for distance VA which was better with the control lenses ( P <0.05; difference of two logMAR letters). End of day comfort was greater with the test lens, but this did not reach significance. Both lenses demonstrated similar scores for overall satisfaction. 87.5% of participants indicated the environmental impact of contact lenses to be important/extremely important to them, with 100% of participants identifying the flat pack packaging as having a smaller environmental impact. CONCLUSION: Overall, the lenses used in the study performed to similar levels. Environmental credentials are important to contact lens wearers, which may contribute to overall lens preference.


Assuntos
Lentes de Contato Hidrofílicas , Humanos , Acuidade Visual , Estudos Cross-Over , Satisfação do Paciente , Equipamentos Descartáveis
16.
JAMA Surg ; 158(11): 1216-1217, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37672247

RESUMO

This life cycle assessment compares the environmental footprint of reusable surgical head covers with single-use disposable surgical head covers.


Assuntos
Equipamentos Descartáveis , Meio Ambiente , Humanos
17.
Science ; 381(6662): eadd9884, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37676957

RESUMO

Rising consumer demand for online food delivery has increased the consumption of disposable cutlery, leading to plastic pollution worldwide. In this work, we investigate the impact of green nudges on single-use cutlery consumption in China. In collaboration with Alibaba's food-delivery platform, Eleme (which is similar to Uber Eats and DoorDash), we analyzed detailed customer-level data and found that the green nudges-changing the default to "no cutlery" and rewarding consumers with "green points"-increased the share of no-cutlery orders by 648%. The environmental benefits are sizable: If green nudges were applied to all of China, more than 21.75 billion sets of single-use cutlery could be saved annually, equivalent to preventing the generation of 3.26 million metric tons of plastic waste and saving 5.44 million trees.


Assuntos
Equipamentos Descartáveis , Poluição Ambiental , Serviços de Alimentação , Plásticos , Resíduos Sólidos , China , Poluição Ambiental/prevenção & controle , Alimentos , Humanos
19.
Indian J Ophthalmol ; 71(7): 2914-2915, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37417148
20.
Anaesth Crit Care Pain Med ; 42(5): 101276, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37437711

RESUMO

INTRODUCTION: Consumption of single-use medical devices has increased considerably, contributing to the excessive wastage produced during surgical procedures. The present study aimed to describe a methodology to assess the transition from single-use blades (SUB) to reusable laryngoscope blades (RUB) and to assess the ecological and economic impact of the switch. METHODS: The ecological analysis was based on the life cycle assessment method. Based on 30 operating rooms in a single tertiary university hospital, the economic analysis compared the usual SUB supplier with four RUB suppliers considering different costs: blade purchasing and depreciation, reprocessing, logistics and waste management. RESULTS: In 2021, 17,200 intubations were performed requiring about 147 RUBs. Switching from SUB to RUB led to an annual saving of 26.5 tons of CO2eq (global warming impact), equivalent to 120 000 km by car. It avoids the extraction of 6.6 tons Oileq (petroleum) and 579 kg of copper (mineral resources) per year. This action also leads to a land occupation reduction of 626 m2 per year and water savings of 221.6 m3 per year. The average cost per intubation varies from 3.16 [3.15-3.16] for SUB to 2.81 [2.77-2.85] for RUB, representing an average saving of 0.35 per intubation leading to 5783.50 annual gain [5074.00-6192.00]. RUB are preferable from 3 and 86 uses from an ecological and economic viewpoint, respectively. CONCLUSION: In a model of 17,200 intubations /year, switching SUD to RUB would save 26.5 tons of CO2eq and 6.6 tons of Oileq with 5783.50 annual gain. RUBs are ecologically and cost-effective after 3 and 86 uses, respectively.


Assuntos
Laringoscópios , Humanos , Análise Custo-Benefício , Intubação Intratraqueal/métodos , Equipamentos Descartáveis , Hospitais Universitários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...